Fluke 789 ProcessMeter

FLUKE 789

Key features

  • Compact digital multimeter and mA loop calibrator solution

  • Full-featured mA loop calibrator with built-in 24v Loop Power

  • Quickly and easily troubleshoot every part of a control loop

  • Large, bright dual-measurement display

Specifications: Fluke 789 ProcessMeter™

Specifications

DC measurement

Range

0-1 A DC

Resolution

1 mA

Accuracy

0.2% + 2 LSD

Range

0-30 mA

Resolution

0.001 mA

Accuracy

0.05% + 2 LSD

AC measurement

Range

0-1 A AC

Resolution

1 mA

Accuracy (25 Hz to 2 kHz)

+/- 1% +2 LSD

Current sourcing

Range

0-20 mA or 4-20 mA

Resolution

0.001 mA

Accuracy

0.05% of span

Drive capability

24 V Compliance or 1200 Ω @ 20 mA

Continuity

Beeps for resistance < 100 Ω

Voltage measurement

Range

0-1000 V AC (true-rms) or DC

Resolution

0.1 mV to 1.0 V

Accuracy

0.1% Rdg + 1 LSD (VDC)

Resistance measurement

to 40 MΩ, 0.2% + 1 LSD

Diode test

2.0 V shows diode voltage drop

Display current and % of span

Yes

Auto Step, Auto Ramp

Yes

Environmental Specifications

Operating temperature

-20°C to 55°C

Storage temperature

-40°C to 60°C

Humidity (without condensation)

95% up to 30°C
75% up to 40°C
45% up to 50°C
35% up to 55°C

Temperature coefficient

0.05 x (specified accuracy) per °C (for temperatures < 18°C or > 28°C)

Safety Specifications

Electrical safety

Designed in accordance with IEC 61010-1: Pollution Degree 2

Overvoltage category

IEC 61010-2-033: CAT IV 600 V / CAT III 1000 V

Maximum voltage

1,000 V

Mechanical and General Specifications

Size (H x W x L)

50 x 100 x 203 mm (1.25 x 3.41 x 7.35 in)

Weight

610 g (1.6 lbs)

Batteries

4 AA alkaline batteries

Warranty

3 years

Battery life

140 hours typical (measurement), 10 hours typical (sourcing 20 mA)

Shock and vibration

Random, 2 g, 5-500 Hz
1 meter drop test